15MPa Red Ig100 Cylinder Fire Extinguishing Equipment Fire-Fighting System
IG100 gas extinguishing equipment uses 100% pure nitrogen as extinguishing agent. IG100 fire extinguishing agent is the main component of air, ozone depletion potential value is zero, global warming potential value is zero, atmospheric retention time is zero, without any adverse effect on the environment. IG100 extinguishing agent is colorless, tasteless, non-toxic, non-corrosive, non-conductive; It is not only harmless to human body, but also does not produce any chemical substances in the process of extinguishing the fire, which will not cause secondary pollution to the equipment. There is no atomization phenomenon when spraying, which can ensure the orderly and safe evacuation of personnel. IG100 is 0.97 relative to air, so that it can maintain a constant fire extinguishing concentration after release in the protection zone, so as to ensure the fire extinguishing effect and effectively prevent reignition. IG100 gas fire extinguishing agent is non-toxic and harmless to human body. It is a safe and environmental protection gas fire extinguishing agent. It is suitable for the place where people often work.
Item |
QMD15/90 |
QMD20/82 |
Operating temperature range(ºC) |
-10~+50 |
Decompression mode |
Decompressor |
Pressure reducing valve |
Storage pressure of fire extinguishing agent cylinder assemblies (+20ºC)MPa |
f15 |
20 |
Maximum working pressure of fire extinguishing agent cylinder assemblies (+50ºC)MPa |
17.2 |
23.2 |
Fire extinguishing agent bottle assemblies specifications (L) |
90 |
82 |
Filling capacity of extinguishing agent (Kg) |
16.8 |
19.2 |
Actuator cylinder specification(L) |
8 |
Storage pressure of actuator cylinder(+20ºC)MPa |
6.0 |
Maximum operating pressure of actuator cylinder (+20ºC)MPa |
6.6 |
Working voltage(V) |
DC24 |
Working current(A) |
1.5A |
Spraying time(S) |
≤60 |
Starting method |
Automatic, manual, mechanical emergency |
System type |
Unit independent, combination distribution, prefabricated type |
Applications And Hazards Protected By Argon Inert Gas Fire Suppression:
controarchives and libraries
civil and marine
computer rooms
control rooms
data centers
educational institutions
electric and electronic applications
electrical switch rooms
financial centers and banks
floating roof tanks protection
egenerators
hospitals
hot process areas
laboratories
libraries
machinery spaces
mass transit
medical facilities
installations
storage centres
vehicles
mining facilities
museums and art galleries
nuclear facilities
offices
offshore platforms
oil & gas facilities
pharmaceutical industry
power plants
telecommunication centers
Features And Benefits From Argon Gas Fire Suppression System
Suitable for occupied areas
Electrically non - conductive
Chemically inert
Colourless, odourless and flavourless
No residue to clean up after the discharge
Zero Ozone Depletion Potential (ODP)
No greenhouse effect
No global warming impact
No decomposition products
No fog and no loss of post-discharge visibility
Non corrosive/toxic
Stored as a gas
Suitable for occupied areas
Excellent post-discharge visibility
Very low refill cost.
Easy to obtain anywhere in the world
Only agent approved for automatic use in manned environmentserators
In the event of discharge, the agent is cost effective to replace
No evacuation issues
Cylinders can be remote from the risk
Directional valve solutions to enable mutli-risks to be protected economically using single cylinder bank
Constant flow solution available, therefore reducing size of venting requirement
Large safety margin
Future proof - no risk of being banned
Economical installation costs
Zero Ozone Depletion Potential (ODP)
We simply borrow Nitrogen and Argon from nature.
When released, they automatically return to their natural place in the environment.
Zero Global Warming Potential (GWP)
Nitrogen and Argon have no atmospheric lifetime and zero GWP, so they pose no risk to the environment.
Weight Similar To Air
The weight of inert gas agents corresponds closely to that of normal air and will evacuate a protected area slower than halocarbon agents after a discharge.
No Combustion By-Products Inert gasses do not decompose into toxic or corrosive elements in a fire, making it a safe choice for people and assets.
No Fogging inert gas systems is ideal for occupied spaces because escape routes remain visible during, and after a discharge.
No Residue That means no damage to your equipment and no clean up required
Electrically Non-conductive It is electrically non-conductive and is therefore highly recommended for protecting electrical and electronic materials.
Minimal Thermal Shock When discharged, inert gasses cause the least amount of thermal shock (sudden temperature drop), compared to other clean agents.hospitals
Company Profile
Successful Cases
Trade Capacity
International Commercial Terms(Incoterms):EXW,FOB, CIF, CFR
Terms of Payment: L/C, T/T
Average Lead Time:
Peak Season Lead Time: one month,
Off Season Lead Time: within 15 workdays
Number of Foreign Trading Staff: 4
Export Percentage: 30%
Main Markets: Southeast Asia
Production Capacity
Factory Address:Jubao Industrial Zone, Qingyuan, Guangdong, China
R&D Capacity:Own Brand, ODM, OEM
No. of R&D Staff: 15
No. of Production Lines:6
Annual Output Value:US$10 -20m
FAQ
Q:Are you a factory or trading company?
A:We are a professional manufacturer. We warmly welcome clients from worldwide to visit our factory and cooperate with us. We can offer OEM & ODM service.
Q:Can you produce goods with special specification?
A:Our company focuses on customized products. First of all, we need to know the specification in details, and then we need to check with our technology department. We will give customers satisfying reply as soon as possible.
Q:How long is the delivery time?
A:45-60 days after the advance payment.
Q:What's your advantage?
A: Independent R&D team, professional production and sales team, great production capacity sustainable supply. Use the best material and production process. Low defective rate.
Q:How can we guarantee quality?
A:Always a pre-production sample before mass production; Always final Inspection before shipment.
Q:Could you supply the samples?
A:Free samples always ready if the value is within our purview.
Q:Can you add some logo on the products?
A:Yes. We could OEM and design your logo.
Q:Are you able to design or explore a new products for us?
A:Yes, we are able to, if the clients could supply the drawings or samples.
Q:How about delivery ?
A:We can send to you by sea/air/express according to you, usually deliver within 7-10 working days after receive deposit.